Solutions Search - LT6108 - High Side Current Sense Amplifier with Reference and Comparator
LTspice: Stepping Parameters
Feb 9th 2012
Plotting voltages or currents in a LTspice simulation is important but so is varying a parameter in a device or model so that you can compare performance and develop your circuit intuition. There are two ways to examine a circuit by changing the value of a parameter. You can either manually enter each value then re-simulate ...
DC1699A-B - LT6108-2 | High Side Current Sense Amplifier w/ Reference and a Comparator
Oct 6th 2011
DC1699A-B - Demo Board for:LT6108 - High Side Current Sense Amplifier with Reference and Comparator
...
DC1699A-A - LT6108-1 | High Side Current Sense Amplifier w/ Reference and a Comparator
Oct 6th 2011
DC1699A-A - Demo Board for:LT6108 - High Side Current Sense Amplifier with Reference and Comparator
...
Circuit Fault Protection with Very Fast Latching Load Disconnect
Sep 7th 2011
The LT6108 is a complete high side current sense device that incorporates a precision current sense amplifier, an integrated voltage reference and a comparator. Two versions of the LT6108 are available. The LT6108-1 has a latching comparator and the LT6108-2 has a non-latching comparator. In addition, the current sense amplifier ...
LT6108 Simplified DC Motor Torque Control
Sep 7th 2011
The LT6108 is a complete high side current sense device that incorporates a precision current sense amplifier, an integrated voltage reference and a comparator. Two versions of the LT6108 are available. The LT6108-1 has a latching comparator and the LT6108-2 has a non-latching comparator. In addition, the current sense amplifier ...
Overcurrent Battery Fault Protection
Sep 7th 2011
The LT6108 is a complete high side current sense device that incorporates a precision current sense amplifier, an integrated voltage reference and a comparator. Two versions of the LT6108 are available. The LT6108-1 has a latching comparator and the LT6108-2 has a non-latching comparator. In addition, the current sense amplifier ...
Energy-Tripped Circuit Breaker Trips After a Time Interval That Varies as a Function of Sensed Load Current
Sep 7th 2011
The circuit of this circuit has three distinct parts – circuit breaking, current sensing and timing. The circuit breaking function can be any type of electronically controlled relay or solid state switch, properly sized for voltage and current ratings of the load being protected. Load current sensing is achieved via ...