Solutions Search - LT6011 - Dual/Quad 135µA, 14nV/rtHz, Rail-to-Rail Output Precision Op Amp

Hall Sensor Amplifier Optimizes Sensitivity vs Supply Current

Mar 1st 2004
Voltage across HALL-ELEMENT bridge is reduced to minimize bridge current from 2.5mA or 230µA then a dual LT6011 DC precision low current low drift and Vos OP AMP is used in an instrumentation AMP configuration at a gain of 101 to give a sensitivity of 40mV/mT. ...

Circuit 

 

DAC Reference Inverter and I-to-V Converter

Aug 23rd 1995
LT6011 dual op amp performs two functions - inverting a positive ref voltage to a negative ref voltage to allow bipolar output polarities and performing the current to voltage conversion on the DAC's current outputs as well buffering the outputs. ...