System Monitor with Instrumentation-Grade Accuracy Used to Measure Relative Humidity

Aug 18th 2011
A psychrometer is a type of hygrometer, a device that measures relative humidity. It uses two thermometers, one dry (dry bulb) and one covered in a fabric saturated with distilled water (wet bulb). Air is passed over both thermometers, either by a fan or by swinging the instrument, as in a “sling psychrometer.” A psychrometric ...

Circuit 

 

Wet Bulb Psychrometer

Sep 3rd 2010
The LTC2990 is used to monitor system temperatures, voltages and currents. Through the I2C serial interface, the device can be configured to measure many combinations of internal temperature, remote temperature, remote voltage, remote current and internal VCC. The internal 10ppm/°C reference minimizes the number of supporting ...

Circuit 

 

Relative Humidity Sensor

Mar 2nd 1999
This sensor is a capacitive element that changes value with humidity. By charging the sensor with a fixed current for a fixed time interval, a voltage is developed that is directly proportional to the sensor capacitance value. ...

Circuit 

 

Relative Humidity Sensor Digitizer-Charge Pump Based

Jul 15th 1998
Hygrometer Digitizer Has 0.3% Accuracy, Although Sensor Must Float Off-Ground. Humidity Sensor Determines Charge Delivered to A1 Integrator During Each Charge Pump Cycle. Resultant A1 Output Ramp Is Reset by Level Triggered C1 via Q1. Output Frequency, Taken at C1, Varies with Humidity ...

Circuit 

 

Relative Humidity Sensor Digitizer-Time Domain Bridge Based

Jul 15th 1998
Humidity Transducer Digitizer Has Grounded Sensor, 1% Accuracy; Trim Scheme Allows Low Tolerance Sensors. Clocked Q1A-Q1B Configurations Produce Ramp Outputs. Q1A Ramp Slope Varies with Humidity Sensor Value, Q1B Ramp Represents Sensor’s Offset (0% RH does not equal 0pF). C1, C2 Digitize Ramp Times. Gate Extracts Time Difference, ...

Circuit 

 

Relative Humidity Sensor Digitizer-Hetrodyne Based

Jun 5th 1998
Hetrodyne Based Humidity Transducer Digitizer Has Grounded Sensor, 2% Accuracy. Capacitively Sensed Hygrometer Beats Humidity Dependent Oscillator (C1) Against Stable Oscillator O1. Difference Frequency Is Demodulated by Q1, Converted to Pulse Form at C2. Counters Scale Output for 0kHz to 1kHz = 0% to 100% Relative Humidity ...

Circuit 

 

Humidty Sensor To Data Aquisition System Interface

Jan 1st 1987
The circuit shown in the schematic features zero drift operational amplifiers (LTC1250 and LTC1050) and a precision instrumentation switched capacitor block (LTC1043). This design will maintain excellent DC accuracy down to microvolt levels. This method was chosen over the use of a true RMS-to-DC or log converter because of ...

Circuit